Solar Thermal Inspection
Every module flown and read for the defects that cost generation — hot cells, bypass-diode and substring failures, whole-panel outages — returned as a located, classified defect list rather than a picture of the array. Quoted by system size in MWp, the way the industry quotes it.
Findings report · Radiometric · CSV · KML · GeoJSON
Transmission Structure Inspection
Every structure photographed to a full shot list — ID tag, each insulator string at both ends, attachment hardware, shield wire, dampers, crossarms and foundation — plus a thermal read of connections under load. Findings ranked by severity and filed by your structure IDs. Corona needs a UV camera and isn't included.
JPG · Radiometric · PDF report · KML · GeoJSON
Distribution Pole Inspection
A consistent five-shot set of every pole top — crossarms, insulators, cutouts, arresters, transformers and connectors — with a thermal read, tagged to your pole IDs and ranked by severity. Built for wildfire-mitigation and reliability programs.
JPG · Radiometric · CSV · KML · GeoJSON
Substation Thermography
Radiometric thermal of bus, switches, bushings and breakers from angles a ground survey can't reach — flown at night or overcast near peak load, every anomaly ranked by temperature rise against NETA guidance or your own criteria.
Radiometric JPG · PDF report · CSV · KML · GeoJSON
Wind Turbine Blade Inspection
Every blade on all four faces — leading edge, trailing edge, pressure and suction sides — photographed root to tip from a safe standoff with the long zoom, defects located by blade, face and radius and ranked by severity.
JPG · PDF report · CSV
Thermal Inspection
Radiometric thermal imaging of one asset, where every pixel carries a measured temperature — hot connections on electrical gear, failing mechanical plant, heat loss at roof penetrations — read and reported per asset.
Radiometric JPG · PDF report
RGB Inspection
A methodical visual survey of one structure — close-up zoom imagery of every face, connection and fitting, returned as an organized photo set and a findings report.
JPG · PDF report
IR Roof Moisture & Envelope Survey
Aerial infrared survey of the roof and walls, mapped onto a 3D model of the building so every indication has a location. Roofs are flown for ASTM C1153 conditions to locate wet insulation; walls are read for insulation gaps and thermal bridges (ASTM C1060). Delivered as capture for a certified thermographer to verify and sign — C1153 calls for core samples before a wet area is confirmed.
Radiometric · OBJ · PDF
Roof IR Scan
A quicker, lower-cost first look at the roof deck alone — radiometric imagery showing where a roof may be holding water or losing heat, without the wall passes or the 3D model. The step before a full moisture survey.
Radiometric · PDF
Hail & Storm Roof Assessment
Commercial roofs after hail or wind: zoom documentation of impacts on the membrane, flashings and soft metals, plus a night infrared pass for insulation that took on water. It documents condition — cause and coverage stay with the adjuster.
JPG · Radiometric · PDF report